AZ Instrument Corp. strives to research and develop quality, energy-efficient Pocket Type to benefit the consumers. We can manufacture professional hygrometer, digital psychrometer, handheld hygrometer that meet specific requirements. Our first responsibility is to completely satisfy the needs of the people and organizations that use and distribute our products while providing the best value solutions for their Professional Hygrometer with Probe requirements. Customer service is another commitment we take seriously, our proven reputation and record of quality support won't leave you stranded.
Handheld hygrometer designed for stable long-term humidity monitoring

8706N AZ

Professional Hygrometer with Probe

Welcome to check the Features, Application, Specification, YouTube of 8706N AZ Pocket Type Digital Psychrometer with External Temperature Probe as follows
Features :

AZ 8706N Stable Humidity Meter with External Probe is developed under high-quality manufacturing processes to ensure reliability and safety:
ISO 9001 Facility: Manufactured in an ISO 9001 certified environment.
CE EN 61326-1: Designed and tested to meet European EMC safety standards.
RoHS & REACH Compliant: We provide a Manufacturer’s Self Declaration, ensuring the product meets environmental safety standards for hazardous substances.

AZ 8706N Hygrometer-probe features:
* Triple display: Temperature, Humidity, External Probe Temperature
* Digital sling psychrometer
* Easy to carry, pocket size with rotate cap design to protect sensors
* Optional external penetrate probe for measuring food quality
* Low battery indication
* Fast response and accurate reading
* Microprocessor circuitry for reliability
* Auto power off time frame switchable
* Disable power off

Application :

Application of 8706N AZ digital thermo hygrometer:
The 8706N AZ thermo hygrometer is designed as pocket size, battery operated easily. It can measure the air Temperature, external temperature and Relative Humidity. Its humidity RH% sensor is protected by rotate cap, and it could be calibrated with calibrated easily with the 33% and 75% salt bottle.

The 8706N AZ Psychrometer could attach the external temperature probe. The Psychrometer is microprocessor based design. It could be used as the best humidity monitoring tool for the HVAC engineer school, factory, warehouse, workspace, laboratories, basement, wine cellar or other controlled environment. No need to whirl the meter or refer to the chart.

The 8706N AZ temperature humidity meter was being designed and manufactured by AZ Instrument, a well experienced manufacturer for Environmental Measuring Instrument.

Specification :

Specification of 8706N AZ digital thermo hygrometer:

Model 8706N
Temperature Range -20~50℃
Temperature Resolution 0.1℃, 0.1℉
Temperature Accuracy ±0.6℃
Humidity Range 0.1~99.9% RH
Humidity Resolution 0.1% RH
Humidity Accuracy ±3%RH (at 25℃ 10~90%RH, others ±5%RH)
External Temperature Probe -20~70℃
External Temperature Accuracy ±0.6℃ (-20~50℃), ±1.2℃ others
Response Time 60 Seconds Typical
LCD Size 33(L) * 28(W) mm
Operating Temperature 0~50℃
Operating RH% Humidity <80%
Storage Temperature -20~50℃
Storage RH% Humidity <90%
Meter Size 178.5(L) * 48.4(W) * 24.7 (H) mm
Weight ~100g
Battery AAA *2 PCS
Standard Package Meter, Batteries, Manual, Paper Box
Optional Accessory Calibration Kits, External Temperature Probe

Youtube :

Welcome to learn more about the 8706N Hygrometer Unboxing Video (as same as 8706)

FAQ :

【FAQ of AZ 8706N Professional Hygrometer with Probe】
Q1: Why does the AZ 8706N provide better long-term humidity stability?
A: The 8706N is designed with a humidity sensing structure that allows system-level calibration and compensation, helping maintain stable performance over long-term use.

Q2: Does the AZ 8706N use an integrated humidity IC?
A: No. The AZ 8706N does not rely on an integrated humidity IC. This design allows better control of signal processing and compensation, improving stability in demanding environments.

Q3: What are the advantages of using an analog RH sensor compared to an IC-based humidity sensor?
A: Analog RH sensors allow greater control over signal processing, calibration, and compensation at the system level. Compared to IC-based humidity sensors, this design offers better long-term stability, improved performance in high-humidity environments, and greater reliability for continuous or industrial applications.

Send Message
Contact Information

By submitting your contact information, you acknowledge that you consent to our processing data in accordance with the Privacy and Cookie Policy.

As one of the most reliable supplier in Taiwan, we supply Professional Hygrometer with Probe with the finest quality. We are the global leader in electrical supplies. We develop, manufacture and distribute groundbreaking Professional Hygrometer with Probe that shatter the status quo and help customers gain and maintain a competitive edge. After knowing the above information, if you want to know more, please come to us. We will provide the information you need and offer high quality Professional Hygrometer with Probe to you at the best price.