8723 AZ
HVAC Humidity Meter & Probe
Welcome to check the Features, Application, Specification of AZ 8723 Portable Temperature Humidity with Remote Humidity Probe as follows
Features
AZ 8723 Humidity Meter, Remote Probe, Dew Point & Wet Bulb is developed under high-quality manufacturing processes to ensure reliability and safety:
ISO 9001 Facility: Manufactured in an ISO 9001 certified environment.
CE EN 61326-1: Designed and tested to meet European EMC safety standards.
RoHS & REACH Compliant: We provide a Manufacturer’s Self Declaration, ensuring the product meets environmental safety standards for hazardous substances.
AZ 8723 Handheld Hygrometer features:
* Dual display temperature and humidity
* RH% / Temperature / Dew Point / Wet Bulb Temperature
* Use high quality capacitance polymer sensor
* Professional remote humidity probe
* Remote probe replaceable & extending measurement
* Dew Point calculated in seconds
* Wet Bulb calculated in seconds
* Fast response and accurate reading
* Easy to read big LCD display
* Maximum, minimum and reset function
* Backlight function included
* Easy humidity self-calibration by optional salt kits
* Unit C/F switchable
* Low battery indicator
* Tripod mountable for long time use
* Microprocessor circuitry for reliability
* Sleep and non-sleep switchable
ISO 9001 Facility: Manufactured in an ISO 9001 certified environment.
CE EN 61326-1: Designed and tested to meet European EMC safety standards.
RoHS & REACH Compliant: We provide a Manufacturer’s Self Declaration, ensuring the product meets environmental safety standards for hazardous substances.
AZ 8723 Handheld Hygrometer features:
* Dual display temperature and humidity
* RH% / Temperature / Dew Point / Wet Bulb Temperature
* Use high quality capacitance polymer sensor
* Professional remote humidity probe
* Remote probe replaceable & extending measurement
* Dew Point calculated in seconds
* Wet Bulb calculated in seconds
* Fast response and accurate reading
* Easy to read big LCD display
* Maximum, minimum and reset function
* Backlight function included
* Easy humidity self-calibration by optional salt kits
* Unit C/F switchable
* Low battery indicator
* Tripod mountable for long time use
* Microprocessor circuitry for reliability
* Sleep and non-sleep switchable
Application
Application of 8723 AZ Portable Temperature Humidity
Meter:
The Portable 8723 AZ Thermo RH% Meter is a micro processor based design. It has the remote humidity probe, which can measure the air relative humidity for different measuring purposes, and it can be calibrated easily with the 33% and 75% salt bottle. Its back-light function could let user to operate in the dark area.
The 8723 AZ Handheld Dew Point & Wet Bulb Temperature Meter also can measure the air temperature, dew point temperature and dew point temperature. User could attach the meter to the tripod for the long-time measurement. It could be used as the best humidity monitoring tool for the school, factory, warehouse, workspace, laboratories, basement, wine cellar or other controlled environment. The 8723 AZ Psychrometer is a must device for HVAC engineers use. No need to whirl the meter or refer to the chart. Easy to get the wet bulb and dew point quickly!
The 8723 AZ Handheld Dew Point & Wet Bulb Temperature Meter with external RH sensor probe was being designed and manufactured by AZ Instrument, a well experienced manufacturer for Environmental Measuring Instrument.
The Portable 8723 AZ Thermo RH% Meter is a micro processor based design. It has the remote humidity probe, which can measure the air relative humidity for different measuring purposes, and it can be calibrated easily with the 33% and 75% salt bottle. Its back-light function could let user to operate in the dark area.
The 8723 AZ Handheld Dew Point & Wet Bulb Temperature Meter also can measure the air temperature, dew point temperature and dew point temperature. User could attach the meter to the tripod for the long-time measurement. It could be used as the best humidity monitoring tool for the school, factory, warehouse, workspace, laboratories, basement, wine cellar or other controlled environment. The 8723 AZ Psychrometer is a must device for HVAC engineers use. No need to whirl the meter or refer to the chart. Easy to get the wet bulb and dew point quickly!
The 8723 AZ Handheld Dew Point & Wet Bulb Temperature Meter with external RH sensor probe was being designed and manufactured by AZ Instrument, a well experienced manufacturer for Environmental Measuring Instrument.
Specification
Specification of 8723 AZ Portable Temperature Humidity Meter:
| Model | 8723 |
| Temperature Range | -10~60℃ |
| Temperature Resolution | 0.1℃, 0.1℉ |
| Temperature Accuracy | ±0.6℃ |
| Humidity Range | 0.1~99.9% RH |
| Humidity Resolution | 0.1% RH |
| Humidity Accuracy | ±3%RH (at 25℃ 10~90%RH, others ±5%RH) |
| RH Sensor Type | Capacitance |
| Dew Point Temperature Range | -68~49.9℃ |
| Wet Bulb Temperature Range | -13.4~59.9℃ |
| Response Time | 60 Seconds Typical |
| Backlight | YES |
| LCD Size | 44(L) * 26(W) mm |
| Operating Temperature | 0~50℃ |
| Operating RH% | Humidity <80% |
| Storage Temperature | -20~50℃ |
| Storage RH% | Humidity <90% |
| Meter Size | 175(L) * 70(W) * 33(H) mm |
| Weight | ~150g |
| Battery | AAA * 4PCS |
| Probe | Product number: VZ872PAZ |
| Standard Package | Meter, Probe, Battery, Manual, Carry Case |
| Optional Accessory | Calibration Kits |
FAQ
【FAQ of AZ 8723 Humidity Meter, Remote Probe, Dew Point & Wet Bulb】
Q1: Does the 8723 AZ measure Dew Point and Wet Bulb temperatures?
A: Yes. The 8723 AZ is specifically designed for HVAC diagnostics, providing instant digital calculations for both Dew Point (DP) and Wet Bulb (WB) temperatures alongside ambient air temperature and relative humidity.
Q2: Can the humidity sensor on the 8723 AZ be calibrated?
A: Absolutely. The device supports manual humidity self-calibration. Users can maintain high accuracy over time by using optional 33% and 75% salt calibration kits, ensuring reliable performance in professional environments.
Q3: Can AZ 8723 transmit data to a PC in real time?
A: No, however, It ensures "Field-Ready Reliability." Without vulnerable data ports, the 8723 AZ has a more robust internal circuitry and a longer battery life.