8311 AZ
Conductivity Water Monitor
Welcome to check the Features, Application, Specification and YouTube of 8311 AZ Water Quality Conductivity Indicator as follows
Features
The AZ 8311 Conductivity Water Monitor is developed under high-quality manufacturing processes to ensure reliability and safety:
ISO 9001 Facility: Manufactured in an ISO 9001 certified environment.
CE EN 55011 & IEC 61000: Designed and tested to meet European EMC safety standards.
RoHS & REACH Compliant: We provide a Manufacturer’s Self Declaration, ensuring the product meets environmental safety standards for hazardous substances.
8311 AZ Water Quality Conductivity Indicator features:
* To monitor filtered/unfiltered water via conductivity
* Suitable for mobile type water treatment service
* 7 bright LED to indicate the conductivity level
* Built-in temperature compensation
* Pre-calibrated in factory before installation
* Thread size 3/4”NPT and conductivity ranges 90uS/cm
* Application:
-Heating water treatment purity check
-Cooling water treatment purity check
-Water filtering purity check
ISO 9001 Facility: Manufactured in an ISO 9001 certified environment.
CE EN 55011 & IEC 61000: Designed and tested to meet European EMC safety standards.
RoHS & REACH Compliant: We provide a Manufacturer’s Self Declaration, ensuring the product meets environmental safety standards for hazardous substances.
8311 AZ Water Quality Conductivity Indicator features:
* To monitor filtered/unfiltered water via conductivity
* Suitable for mobile type water treatment service
* 7 bright LED to indicate the conductivity level
* Built-in temperature compensation
* Pre-calibrated in factory before installation
* Thread size 3/4”NPT and conductivity ranges 90uS/cm
* Application:
-Heating water treatment purity check
-Cooling water treatment purity check
-Water filtering purity check
Application
Application of 8311 AZ Water Quality Conductivity Indicator:
The 8311 AZ Water Quality Conductivity Indicator built-in temperature compensation, pre-calibration, and clear LED indicators make it user-friendly and reliable for professionals in following fields.
1. Heating Water Treatment Purity Check: Ensuring the purity of water used in heating systems to prevent scaling and corrosion.
2. Cooling Water Treatment Purity Check: Monitoring the purity of water in cooling systems to maintain efficiency and prevent damage to equipment.
3. Water Filtering Purity Check: Verifying the effectiveness of water filtration systems by measuring the conductivity of filtered versus unfiltered water.
4. Mobile Water Treatment Services: Ideal for on-the-go water treatment services due to its portability and ease of use.
The 8311 AZ Water Quality Conductivity Indicator was being designed and manufactured by AZ Instrument, a well experienced manufacturer for Environmental Measuring Instrument.
The 8311 AZ Water Quality Conductivity Indicator built-in temperature compensation, pre-calibration, and clear LED indicators make it user-friendly and reliable for professionals in following fields.
1. Heating Water Treatment Purity Check: Ensuring the purity of water used in heating systems to prevent scaling and corrosion.
2. Cooling Water Treatment Purity Check: Monitoring the purity of water in cooling systems to maintain efficiency and prevent damage to equipment.
3. Water Filtering Purity Check: Verifying the effectiveness of water filtration systems by measuring the conductivity of filtered versus unfiltered water.
4. Mobile Water Treatment Services: Ideal for on-the-go water treatment services due to its portability and ease of use.
The 8311 AZ Water Quality Conductivity Indicator was being designed and manufactured by AZ Instrument, a well experienced manufacturer for Environmental Measuring Instrument.
Specification
Specification of 8311 AZ Water Quality Conductivity Indicator:
| Model | 8311 |
| Conductivity Measuring Range | 0~90 us/cm |
| Conductivity Accuracy | ±15% |
| Thread Size | 3/4" NPT |
| IP Rating | IP68 (sensing area only) |
| ATC | ATC |
| LED | #1. green <15 us/cm #2. green <30 us/cm #3. green <45 us/cm #4. green <60 us/cm #5. green <75 us/cm #6. yellow <90 us/cm #7. red flashing >90 us/cm |
| Measuring Temperature | 0~80℃ |
| Measuring Pressure | <10 Bar (145 psi) |
| Operation Environment Temperature |
0~50℃ |
| Storage Temperature | 0~60.0℃ |
| Storage RH% | Humidity <90% |
| Sensor Life Time | >12 months (with good maintenance) |
| Dimension | Body: 67mm (H) x 40mm (Diameter) Electrode: 27mm long, 6mm diameter |
| Weight | 200g |
| Power Supply | 9VDC, <900mA |
| Standard Package | EC indicator, Box, Manual |
Youtube
Welcome to learn more about the 8311 AZ Water Quality Conductivity Indicator from the following YouTube video.
8311 AZ Water Quality Conductivity Indicator Unboxing Video
8311 AZ Water Quality Conductivity Indicator Unboxing Video
FAQ
【FAQ of AZ 8311 Conductivity Indicator: Boiler Limescale Prevention】
Q1: How does the AZ 8311 help prevent limescale in boiler systems?
A: The AZ 8311 Conductivity Indicator provides real-time monitoring of feed water purity. By detecting high mineral content (high conductivity), it alerts technicians to stop filling before hard water enters the system. This proactive monitoring is essential for preventing limescale build-up, protecting the boiler’s heat exchanger, and maintaining energy efficiency in hydronic heating systems.
Q2: How does it signal resin exhaustion?
A: When the water softener's resin is saturated, the AZ 8311's LED will turn red (>90 µS/cm). This simple visual cue tells the technician exactly when to replace the filter or regenerate the resin.
Q3: Can it handle standard heating system pressure?
A: Yes. It is rated for up to 10 Bar (145 psi) and features a 3/4” NPT thread, making it safe and easy to install directly into most residential and commercial hydronic heating loops.