88595 AZ EB
NEW

GLP 4 Channel K/J/T/R/S/E Thermocouple Data Logger

Welcome to check the Features, Application, Specification, YouTube of 88595 AZ GLP 4 Channel K/J/T/R/S/E Thermocouple Data Logger as follows
Features

88595 AZ GLP 4 Channel K/J/T/R/S/E Thermocouple Data Logger features:
* Designed to meet Good Laboratory Practice (GLP), password access control is included.
* Extra-large LCD with dual-color adjustable backlighting for enhanced visibility
* Multi-cycle start/stop logging functionality and software-free data download to PC
* High/low alarm & temperature offset of each channel is individually programmable

Application

Application of 88595 AZ GLP 4 Channel K/J/T/R/S/E Type Thermocouple Logger:

The 88595 AZ K/J/T/R/S/E Type Temperature Recorder is suitable for various applications where precise temperature monitoring and data recording are essential. 

1. Laboratory Research and Experimentation
- Why it fits:

The 88595 AZ 4 Channel K/J/T/R/S/E Type Temperature Recorder is designed to meet Good Laboratory Practice (GLP) standards with password access control, ensuring data integrity and security—crucial for controlled experiments in scientific research.

- Use case:
Monitoring temperature in chemical reactions, biological incubations, or material testing, where multiple samples need simultaneous tracking (using the 4 channels). The high/low alarm feature can alert researchers to deviations, and the temperature offset allows calibration for accuracy.

2. Food Safety and Quality Control
- Why it fits:
The ability to log temperature data over time and download it without software simplifies compliance with food safety regulations (e.g., HACCP).

The extra-large LCD with adjustable backlighting ensures readability in various environments, like kitchens or storage areas.

- Use case:
Tracking temperatures in ovens, refrigerators, or during food transport across multiple points. Programmable alarms can signal when food exceeds safe temperature thresholds.

3.Industrial Process Monitoring
- Why it fits:
The multi-cycle start/stop logging functionality is ideal for processes that require periodic temperature checks, and the 4-channel capability supports monitoring multiple zones or equipment simultaneously.

- Use case:
Overseeing temperature in manufacturing processes (e.g., metal forging, plastic molding, or HVAC systems), with alarms set to prevent overheating or equipment failure. Data can be downloaded for quality assurance reports.

4. Pharmaceutical and Medical Storage
- Why it fits:
GLP compliance and secure access make t
he 88595 AZ 4 Channel K/J/T/R/S/E Type Temperature Recorder suitable for environments requiring strict regulatory oversight. The high/low alarm feature ensures temperature-sensitive materials stay within required ranges.

- Use case:
Monitoring storage conditions for vaccines, drugs, or biological samples in cold chains or incubators, with data logs providing an audit trail for compliance.

5. Environmental Monitoring
- Why it fits:
The
88595 AZ 4 Channel K/J/T/R/S/E Type Temperature Data Logger’s flexibility with programmable offsets and multi-channel logging supports tracking temperature variations across different locations or conditions.

- Use case:
Measuring temperature in climate studies, greenhouses, or server rooms, where maintaining specific ranges is critical. The dual-color backlit LCD enhances visibility in fieldwork settings.

6. Educational and Training Purposes
- Why it fits:
The user-friendly design (software-free data download, clear display) makes it accessible for students or trainees learning about temperature measurement and data logging.

- Use case:
Classroom experiments demonstrating thermodynamics or heat transfer, with the ability to log and analyze data from multiple thermocouples.


The 88595 AZ GLP 4 Channel K/J/T/R/S/E Type Thermocouple Data Logger is well-suited for applications requiring reliable, multi-point temperature monitoring with secure, easy-to-access data recording—spanning research, industry, food safety, pharmaceuticals, environmental studies, and education. 

The
88595 AZ GLP 4 Channel K/J/T/R/S/E Type Thermocouple Data Logger was being designed and manufactured by AZ Instrument, a well experienced manufacturer for Environmental Measuring Instrument.

Specification

Specification of 88595 AZ GLP 4 Channel K/J/T/R/S/E Thermocouple Data Logger:


Model 88595
K Temp. Range -200~1370℃, -328~2498℉
J Temp. Range -200~760℃, -328~1400℉
T Temp. Range -200~390℃, -328~730℉
R Temp. Range 0~1760℃, 32~3200℉
S Temp. Range 0~1760℃, 32~3200℉
E Temp. Range -200~736℃, -328~1356℉
Buzzer ~70 dB at 10cm distance
Temp. Resolution Above 1000 ℃/℉ is 1 ℃/℉
Below 
1000 ℃/℉ is 0.1 ℃/℉
Temp. Accuracy ± 0.5℃ for under 1000℃, 1℃ for above
± 0.9℉ for under 1832℉ , 1.8℉ for above
Backlight Blue and Red (red for alarm)
Memory 48,000 records for auto logging
99 reocrds for manual logging
Sampling Rate 1, 2, 5, 10, 15, 30 sec
1, 2, 5, 10, 15, 30, 60, 90 min
Start Delay 0, 1, 5, 10, 30 min
1, 2, 5, and 24 hrs 
Power Built-in rechargeable 3.7V Li battery
with USB Type C port
Consumption <6.5mA (BLT off); <30mA (BLT on)
>120 working hours (BLT/Buzzer off)
LCD Size 60(L) * 75(W) mm
Operating Temperature 10~60℃
Operating RH% Humidity <80%
Storage Temperature -20~50℃
Storage RH% Humidity <90%
Meter Size 180(L) * 75(W) * 50(H) mm
Weight ~200g
Standard Package Meter, Class 1 K bead Thermocouple 4PCS,
Manual, Carry case, USB-C cable
Optional Accessory IR printer, Universal adaptor
Youtube

Welcome to learn more about the 88595 AZ GLP 4 Channel K/J/T/R/S/E Thermocouple Data Logger from the following product introduction video via YouTube.


88595 AZ GLP 4 Channel K/J/T/R/S/E Thermocouple Data Logger Operation Video


88595 AZ GLP 4 Channel K/J/T/R/S/E Thermocouple Data Logger Unboxing Video